        Human Retinol binding protein(RBP )ELISA Kit

        發布時間: 2012-02-14  點擊次數: 2065次

        Human Retinol binding protein(RBP )ELISA Kit
        Assay range:80μg/L -2000μg/L 96 determinations
        Purpose
        This kit allows for the determination of RBP concentrations in Human serum, cell culture supernates and other biological fluids

        Principle of the assay
        The kit assay Human RBP level in the sample,use Purified Human RBP antibody to coat microtiter plate wells, make solid-phase antibody, then add RBP to wells, Combined antibody which With HRP labeled goat anti-Human become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human RBP in the samples is then determined by comparing the O.D. of the samples to the standard curve.


        Materials provided with the kit

        1Human Retinol binding protein(RBP )ELISA Kit

        wash solution
        20ml×1bottle
        7
        Stopp Solution
        6ml×1 bottle

        2
        HRP-Conjugate reagent
        6ml×1 bottle
        8
        Standard(4000μg/L)
        0.5ml×1 bottle

        3Human Retinol binding protein(RBP )ELISA Kit

        Microelisa stripplate
        12well×8strips
        9
        Standard diluent
        1.5ml×1bottle

        4
        Sample diluent
        6ml×1 bottle
        10
        Instruction
        1

        5
        Chromogen Solution A
        6ml×1 bottle

        11
        Closure plate membrane
        2

        6
        Chromogen Solution B
        6ml×1 bottle
        12
        Sealed bags
        1
         


        Specimen requirements
        1. extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles.
        2. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

        Assay procedure
        1. Dilute and add sample:Dilute Original density Standard as follow table:
         

        2000μg/L
        5 Standard
        150μl Original density Standard+150μl Standard diluent

        1000μg/L
        4 Standard
        150μl 5 Standard+150μl Standard diluent

        500μg/L
        3 Standard

        150μl 4 Standard+150μl Standard diluent

        250μg/L
        2 Standard

        150μl 3 Standard +150μl Standard diluent

        125μg/L
        1 Standard
        150μl 2 Standard +150μl Standard diluent

         


        2.add sample:Set blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.
        3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37℃.
        4.Configurate liquid: 30-fold wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.
        5.washing:Uncover Closure plate membrane, discard Liq
        uid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.
        6.add enzyme:Add HRP-Conjugate reagent 50μl to each well, except blank well.
        7.incubate:Operation with 3.
        8.washing:Operation with 5.
        9.color:Add Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37℃
        10.Stop the reaction:Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).
        11.assay:take blank well as zero , Read absorbance at 450

        nm after Adding Stop Solution and within 15min.







        Steps description

        Standard, Sample diluent
         

         

         

        Add Standard, Sample diluent, incubate for 30 min at 37℃.
         

         

         

        Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37℃.
         

         

         

        Wash 5 times,Add Chromogen Solution A and B, incubate for 30 min at 37℃.
         

         

         

        Add Stopp Solution
         

         

         

        Read absorbance at 450nm within 15 min
         

         

         

        calculate
         




        Calculate
        Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.

        Important notes
        1. The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
        2. washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
        3. add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .
        4. if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.(×n×5).
        5. Closure plate membrane only limits the disposable use, to avoid cross-contamination.
        6. The substrate evade the light preservation.
        7. Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.
        8. All samples, washing buffer and each kind of reject should according to infective material process.
        9. Do not mix reagents with those from other lots.

        Storage and validity
        1.Storage: 2-8℃.